Transformer LV Short-circuit Impedance Tester ZWZK101
♦The tester enables printing and storage.
♦featured with high testing accuracy, high automation, small in size and light weight.
Product Introduction
Transformer LV Short-circuit Impedance Tester applies to LV load impedance test during delivery, overhaul, trial test and handover test of power transformers (single phase or three-phase).
It tests the short-circuit impedance (%) of power voltage on site and compares it with the value indicated on the nameplate or the factory default to find out any defects including but not limited to winding displacement or deformation due to currents from major failure during transformation, installation or operation following the delivery test. (The short circuit change shall be considered as significant if it exceeds ± 3% as specified in China International Conference on Electricity Distribution 2000 (“CICED 2000”)).
Transformer LV Short-circuit Impedance Tester is not provided with an external voltage regulator and adopts the primary connection mode. It begins the three-phase testing and calculates impedance error percentage automatically when the parameter is entered and provides intuitive results. This is a rapid tester which detects winding deformation of transformers on site.
Functional Characteristics
1. The tester is supplied with AC220V low voltage power to provide current for AB, BC and CA high voltage windings of the transformer automatically; collects data simultaneously and; calculates impedance error percentage automatically with intuitive testing results;
2. The tester completes the three-phase testing automatically in the primary connection mode other then inversed connection with the testing wire;
3. The tester allows either single phase testing or three-phase testing both manually and automatically;
4. The tester achieves output current limit applicable to test item with any impedance;
5. The test item can be measured without an external voltage regulator;
6. The tester functions in measuring zero sequence impedance;
7. The tester functions in measuring inductance;
8. The tester has a large LCD display with a menu in Chinese. Operation are facilitated based on the notes on the display;
9. The tester enables printing and storage and is featured with high testing accuracy, high automation, small in size and light weight.
Technical Parameter
Scope of voltage measurement | 5~400V |
Scope of current measurement | 0.1~20A |
Power frequency | 50Hz |
Ambient humidity | ≤85%RH |
Accuracy of measurement | 0.2d |
Operating power | AC220V±10% |
Operating temperature | -10℃~50℃ |
Net weight | 6kg |